Contents
Via the display on the meter*

* Example for the Landys + Gyr E660 model. The displays may differ depending on the model of the meter.
What data can I see on the screen?
OBIS CODE* |
MEANING |
Offtake |
|
1.4.0 |
Power of the current quarter hour (kW) |
1.5.0 |
Last quarter hour power value (kW) |
1.6.1 |
Quarter-hourly peak of the current month at the peak hours (kW) |
1.6.1.xx |
Quarter-hourly peak of the previous month at the peak hours (kW) |
1.6.2 |
Quarter-hourly peak of the current month at the off-peak hours (kW) |
1.6.2.xx |
Quarter-hourly peak of the previous month at the off-peak hours (kW) |
1.8.1 |
Active energy index of the current month at the peak hours (kWh) |
1.8.1.xx |
Active energy index of the previous month at the peak hours (kWh) |
1.8.2 |
Active energy index of the current month at the off-peak hours (kWh) |
1.8.2.xx |
Active energy index of the previous month at the off-peak hours (kWh) |
5.8.0 |
Inductive energy index for the current month (kVArh) |
5.8.0.xx |
Inductive energy index for the previous month (kVArh) |
8.8.0 |
Capacitive energy index for the current month (kVArh) |
8.8.0.xx |
Capacitive energy index for the previous month (kVArh) |
Injection |
|
2.4.0 |
Power of the current quarter hour (kW) |
2.5.0 |
Last quarter hour power value (kW) |
2.6.1 |
Quarter-hourly peak of the current month at the peak hours (kW) |
2.6.1.xx |
Quarter-hourly peak of the previous month at the peak hours (kW) |
2.6.2 |
Quarter-hourly peak of the current month at the off-peak hours (kW) |
2.6.2.xx |
Quarter-hourly peak of the previous month at the off-peak hours (kW) |
2.8.1 |
Active energy index of the current month at the peak hours (kWh) |
2.8.1.xx |
Active energy index of the previous month at the peak hours (kWh) |
2.8.2 |
Active energy index of the current month at the off-peak hours (kWh) |
2.8.2.xx |
Active energy index of the previous month at the off-peak hours (kWh) |
6.8.0 |
Capacitive energy index for the current month (kVArh) |
6.8.0.xx |
Capacitive energy index for the previous month (kVArh) |
7.8.0 |
Inductive energy index for the current month (kVArh) |
7.8.0.xx |
Inductive energy index for the previous month (kVArh) |
xx = Number of times the counter has been reset to zero |
* The codes available may vary depending on the model of the meter.
Via the pulses
You can also monitor your consumption via the pulses emitted by the meter. This method requires a device which can read these pulses (pulse box), and you then connect a datalogger to this in order to monitor your consumption in real time.

Other tracking methods
- Via your energy supplier: You can also consult your energy supllier, who receives the quarter-hourly data from Sibelga on a daily basis.
- Consumption history: You can also request your consumption history via the Sibelga website.